Canvil logo RUN PIPE SIZES
Anvilets are manufactured to cover as many run sizes as possible per outlet size. The range of run sizes is based on a maximum gap 1/16" between the fitting and the pipe on the largest size of run pipe shown on the fitting. The following chart shows the range of run pipe sizes per outlet size.
STANDARD, EXTRA STRONG and CLASS 3000 FITTINGS. For outlet NPS 5 to 36, order for specific run pipe size.
1/8 3/8 x 1/8
1/2 x 1/8
1 - 3/4 x 1/8
2 1/2 - 1 1/4 x 1/8
36-3 x 1/8
1 1/2 1 1/2 x 1 1/2
2 x 1 1/2
2 1 /2 x 1 1/2
3 x 1 1/2
4 - 3 1/2 x 1 1/2
6 - 5 x 1 1/2
12 - 8 x 1 1/2
24 - 14 x 1 1/2
36 - 26 x 1 1/2

1/4 3/8 x 1/4
1/2 x 1/4
1 - 3/4 x 1/4
2 1/2 - 1 1/4 x 1/4
36 - 3 x 1/4
2 2 x 2
2 1/2 x 2
3 x 2
3 1/2 x 2
4 x 2
5 x 2
6 x 2
10 - 8 x 2
18 - 12 x 2
36 - 20 x 2

3/8 1/2 x 3/8
1 - 3/4 x 3/8
2 1/2 - 1 1/4 x 3 /8
36 - 3 x 3/8
2 1/2 2 1/2 x 2 1/2
3 x 2 1/2
3 1/2 x 2 1/2
4 x 2 1/2
5 x 2 1/2
6 x 2 1/2
8 x 2 1/2
12 - 10 x 2 1/2
18 - 14 x 2 1/2
36 - 20 x 2 1/2

1/2 1/2 x 1/2
3/4 x 1/2
1 x 1/2
1 1/2 - 1 1/4 x 1/2
2 1/2 - 2 x 1/2
8 - 3 x 1/2
36 - 10 x 1/2
3 3 x 3
3 1/2 x 3
4 x 3
5 x 3
6 x 3
8 x 3
10 x 3
14 - 12 x 3
36 - 24 x 3

3/4 3/4 x 3/4
1 x 3/4
1 1/2 - 1 1/4 x 3/4
2 1/2 - 2 x 3/4
5- 3 x 3/4
12 - 6 x 3/4
36 - 14 x 3/4
3 1/2 3 1/2 x 3 1/2
4 x 3 1/2
5 x 3 1/2
6 x 3 1/2
8 x 3 1/2
10 x 3 1/2
14 - 12 x 3 1/2
20 - 16 x 3 1/2
36 - 24 x 3 1/2

1 1 x 1
1 1/4 x 1
1 1/2 x 1
2 x 1
2 1/2 x 1
3 1/2 - 3 x 1
5 - 4 x 1
10 - 6 x 1
36 - 12 x 1
4 4 x 4
5 x 4
6 x 4
8 x 4
10 x 4
14 - 12 x 4
20 - 16 x 4
36 - 24 x 4

1 1/4 1 1/4 x 1 1/4
1 1/2 x 1 1/4
2 x 1 1/4
2 1/2 x 1 1/4
3 1/2 - 3 x 1 1/4
5 - 4 x 1 1/4
8 - 6 x 1 1/4
18 - 10 x 1 1/4
36 - 20 x 1 1/4

CLASS 6000 FITTINGS. For outlet NPS 2 1/2 to 12, order for specific run pipe size.
1/2 1 - 3/4 x 1/2
2 - 1 1/4 x 1/2
6 - 2 1/2 x 1/2
36 - 8 x 1/2
3/4 1 x 3/4
2 1/2 - 1 1/4 x 3/4
10 - 3 x 3/4
36 - 12 x 3/4
1 1 1/2 x 1 1/4 x 1
2 1/2 - 2 x 1
10 - 3 x 1
36 - 12 x 1

11/4 1 1/2 x 1 1/4
2 1/2 - 2 x 1 1/4
3 1/2 - 3 x 1 1/4
8 - 4 x 1 1/4
20 - 10 x 1 1/4
36 - 24 x 1 1/4
1 1/2 2 x 1 1/2
2 1/2 x 1 1/2
3 1/2 - 3 x 1 1/2
5 - 4 x 1 1/2
8 - 6 x 1 1/2
18 - 10 x 1 1/2
36 - 20 x 1 1/2
2 2 1/2 x 2
3 x 2
4 x 2
5 x 2
6 x 2
10 - 8 x 2
12 - 12 x 2
36 - 24 x 2

SCH. 160 & XXS. For outlet NPS 2 1/2 to 12, order for specific run pipe size.
1/2 1/2 X 1/2
1 1/4 - 3/4 X 1/2
36 - 1 1/2 X 1/2
3/4 1 - 3/4 X 3/4
2 - 1 1/4 X 3/4
6 - 2 1/2 X 3/4
36 - 8 X 3/4
1 1 X 1
2 1/2 - 1 1/4 X 1
10 - 3 X 1
36 - 12 X 1

11/4 1 1/2 - 1 1/4 X 1 1/4
2 1/2 - 2 X 1 1/4
10 - 3 X 1 1/4
36 - 12 X 1 1/4
1 1/2 1 1/2 x 1 1/2
2 1/2 - 2 x 1 1/2
3 1/2 - 3 x 1 1/2
8 - 4 x 1 1/2
20 - 10 x 1 1/2
36 - 24 x 1 1/2
2 2 x 2
2 1/2 X 2
3 1/2 - 3 x 2
5 - 4 x 2
8 - 6 x 2
18 -10 x 2
36 - 20 x 2

Example: 12 - 8 x 1 1/2 Note:
If the schedules, or weights, of the branch and run pipe are not the same, then they must be clearly specified.

Example:
3 Sch. 80 x 1 1/2 Sch. 40 BW Anvilet.
12
8
1 1/2
- is the largest run pipe size for which the fitting is applicable.
- is the smallest run pipe size the fitting is applicable.
- is the outlet (branch) size.

[Home Page] [Catalog Index]  [Next Page]