RUN PIPE SIZES | |
| Anvilets are manufactured to cover as many run sizes as possible per outlet size. The range of run sizes is based on a maximum gap 1/16" between the fitting and the pipe on the largest size of run pipe shown on the fitting. | The following chart shows the range of run pipe sizes per outlet size. | |
| STANDARD, EXTRA STRONG and CLASS 3000 FITTINGS. For outlet NPS 5 to 36, order for specific run pipe size. | |||||
| 1/8 | 3/8 x 1/8 1/2 x 1/8 1 - 3/4 x 1/8 |
2 1/2 - 1 1/4 x 1/8 36-3 x 1/8 |
1 1/2 | 1 1/2 x 1 1/2 2 x 1 1/2 2 1 /2 x 1 1/2 3 x 1 1/2 4 - 3 1/2 x 1 1/2 |
6 - 5 x 1 1/2 12 - 8 x 1 1/2 24 - 14 x 1 1/2 36 - 26 x 1 1/2 |
| 1/4 | 3/8 x 1/4 1/2 x 1/4 1 - 3/4 x 1/4 |
2 1/2 - 1 1/4 x 1/4 36 - 3 x 1/4 |
2 | 2 x 2 2 1/2 x 2 3 x 2 3 1/2 x 2 4 x 2 |
5 x 2 6 x 2 10 - 8 x 2 18 - 12 x 2 36 - 20 x 2 |
| 3/8 | 1/2 x 3/8 1 - 3/4 x 3/8 |
2 1/2 - 1 1/4 x 3 /8 36 - 3 x 3/8 |
2 1/2 | 2 1/2 x 2 1/2 3 x 2 1/2 3 1/2 x 2 1/2 4 x 2 1/2 5 x 2 1/2 |
6 x 2 1/2 8 x 2 1/2 12 - 10 x 2 1/2 18 - 14 x 2 1/2 36 - 20 x 2 1/2 |
| 1/2 | 1/2 x 1/2 3/4 x 1/2 1 x 1/2 1 1/2 - 1 1/4 x 1/2 |
2 1/2 - 2 x 1/2 8 - 3 x 1/2 36 - 10 x 1/2 |
3 | 3 x 3 3 1/2 x 3 4 x 3 5 x 3 6 x 3 |
8 x 3 10 x 3 14 - 12 x 3 36 - 24 x 3 |
| 3/4 | 3/4 x 3/4 1 x 3/4 1 1/2 - 1 1/4 x 3/4 2 1/2 - 2 x 3/4 |
5- 3 x 3/4 12 - 6 x 3/4 36 - 14 x 3/4 |
3 1/2 | 3 1/2 x 3 1/2 4 x 3 1/2 5 x 3 1/2 6 x 3 1/2 8 x 3 1/2 |
10 x 3 1/2 14 - 12 x 3 1/2 20 - 16 x 3 1/2 36 - 24 x 3 1/2 |
| 1 | 1 x 1 1 1/4 x 1 1 1/2 x 1 2 x 1 2 1/2 x 1 |
3 1/2 - 3 x 1 5 - 4 x 1 10 - 6 x 1 36 - 12 x 1 |
4 | 4 x 4 5 x 4 6 x 4 8 x 4 |
10 x 4 14 - 12 x 4 20 - 16 x 4 36 - 24 x 4 |
| 1 1/4 | 1 1/4 x 1 1/4 1 1/2 x 1 1/4 2 x 1 1/4 2 1/2 x 1 1/4 3 1/2 - 3 x 1 1/4 |
5 - 4 x 1 1/4 8 - 6 x 1 1/4 18 - 10 x 1 1/4 36 - 20 x 1 1/4 |
|||
| CLASS 6000 FITTINGS. For outlet NPS 2 1/2 to 12, order for specific run pipe size. | ||||||||
| 1/2 | 1 - 3/4 x 1/2 2 - 1 1/4 x 1/2 6 - 2 1/2 x 1/2 36 - 8 x 1/2 |
3/4 | 1 x 3/4 2 1/2 - 1 1/4 x 3/4 10 - 3 x 3/4 36 - 12 x 3/4 |
1 | 1 1/2 x 1 1/4
x 1 2 1/2 - 2 x 1 10 - 3 x 1 36 - 12 x 1 |
|||
| 11/4 | 1 1/2 x 1 1/4 2 1/2 - 2 x 1 1/4 3 1/2 - 3 x 1 1/4 8 - 4 x 1 1/4 |
20 - 10 x 1 1/4 36 - 24 x 1 1/4 |
1 1/2 | 2 x 1 1/2 2 1/2 x 1 1/2 3 1/2 - 3 x 1 1/2 5 - 4 x 1 1/2 |
8 - 6 x 1 1/2 18 - 10 x 1 1/2 36 - 20 x 1 1/2 |
2 | 2 1/2 x 2 3 x 2 4 x 2 5 x 2 |
6 x 2 10 - 8 x 2 12 - 12 x 2 36 - 24 x 2 |
| SCH. 160 & XXS. For outlet NPS 2 1/2 to 12, order for specific run pipe size. | ||||||||
| 1/2 | 1/2 X 1/2 1 1/4 - 3/4 X 1/2 36 - 1 1/2 X 1/2 |
3/4 | 1 - 3/4 X 3/4 2 - 1 1/4 X 3/4 6 - 2 1/2 X 3/4 36 - 8 X 3/4 |
1 | 1 X 1 2 1/2 - 1 1/4 X 1 10 - 3 X 1 36 - 12 X 1 |
|||
| 11/4 | 1 1/2 - 1 1/4
X 1 1/4 2 1/2 - 2 X 1 1/4 10 - 3 X 1 1/4 36 - 12 X 1 1/4 |
1 1/2 | 1 1/2 x 1 1/2 2 1/2 - 2 x 1 1/2 3 1/2 - 3 x 1 1/2 8 - 4 x 1 1/2 |
20 - 10 x 1 1/2 36 - 24 x 1 1/2 |
2 | 2 x 2 2 1/2 X 2 3 1/2 - 3 x 2 5 - 4 x 2 |
8 - 6 x 2 18 -10 x 2 36 - 20 x 2 |
|
| Example: 12 - 8 x 1 1/2 | Note: If the schedules, or weights, of the branch and run pipe are not the same, then they must be clearly specified. Example: 3 Sch. 80 x 1 1/2 Sch. 40 BW Anvilet. |
|
| 12 8 1 1/2 |
- is the largest run pipe size for which the
fitting is applicable. - is the smallest run pipe size the fitting is applicable. - is the outlet (branch) size. |
|
[Home Page] [Catalog Index] [Next Page]